Precision GC Systems Gas Chromatography Machine Top Rate with PC Software and Used in Analytical Chemistry

Precision GC Systems Gas Chromatography M achine Top Rate with PC Software and Used in Analytical Chemistry 1. Introduction of the Gas Chromatograph The gas chromatography machine is include some models, with different accessories , such as detector, colume, etc., it equip with the PC Software,...

Product Catalog

Precision GC Systems Gas Chromatography Machine Top Rate with PC Software and Used in Analytical Chemistry


1. Introduction of the Gas Chromatograph

The gas chromatography machine is include some models, with different accessories , such as detector, colume, etc., it equip with the PC Software, which can be connect to computer for operating.


图片58(001).jpg图片59(001).jpg

图片60(001).jpg


2. Technical Parameters of the Gas Chromatograph Instrument

1). ME-GC9720 Gas Chromatograph

Temperature Control :

Temp. control range:

RT+5℃~450℃(0.1℃increment)

Programming temp.-ramp speed:

0-120℃/min

Fast cool down:

250~100℃≤1.5minutes

Temp. stability: ±0.1℃


Detector System :

Detector

Max. Operating

Temperature

Temp. Control

Accuracy

Sensitivity

FID

450℃

±0.1℃

≤3.0×10-12g/s[Hexadecane]

TCD

400℃

≥10000mV.ml/mg[Hexadecane]

ECD

400℃

≤1.5×10-14g/ml[γ-666]

FPD

450℃

P≤2.0×10-13g/s[Parathion-methyl]; S≤2.0×10-11g/s[Parathion-methyl]

NPD

400℃

N≤1×10-12;

P≤5×10-13g/s[Malathion]


Setup :

Standard Setup

Capillary Inlet

Split/splitless capillary

Packed Inlet

Packed inlet

PC Software

FL9720 or Clarity counter-control software

Optional Sampling Device

Changeover Valve

6-way valve or 10-way valve

Head Space Sampler

HS-9A or HS-16 automatic head space sampler

Heat Analysis Sampler

RJX9700 with temp.-control or RJX9700 without temp.-control

Auto Sampler

10 or 110


Software Features

1). Multi-channel and multi-user universal workstation to control all parameter;

2). Can collect signal from 4 detectors via RS232 or USB;

3). Basic parameter: max sample-collecting frequency @100Hz/unlimited peak process quantity/integral sensitivity @1μV*s;

4). Batch processing makes machine control, auto sampling sequence collecting, auto integral correction much easier;

5). Fully support FDA-21CFR PART 11, SST AND IQ/OQ;

6). Powerful post-treatment facilitate chromatography comparing, re-correction and data input&output.


2). ME-GC9790II Lab Gas Chromatograph

Detector System:

Detector

Max. Operating

temperature

Temp. Control

Accuracy

Sensitivity

FID

400℃

±0.1℃

≤5.0×10-12g/s[Hexadecane]

TCD

400℃

≥8000mV.ml/mg[Hexadecane]

ECD

350℃

≤3×10-14g/ml[γ-666]

FPD

400℃

P≤1.4×10-12g/s[Parathion-methyl] S≤5.0×10-11g/s[Parathion-methyl]

NPD

400℃

N≤1×10-12g/s[Azobenzene];

P≤5×10-13g/s[Malathion]


Column Oven Temperature Control :

Temp. control range: RT+6℃~399℃(0.1℃ increment)

Programming temp.-ramp speed: 0-40℃/min

Programming temp.-ramp:  8 steps

Fast cool down: 350~50℃≤3.5minutes

Temp. stability: ±0.1℃


Accessories :

Standard Accessories

Capillary Inlet

1.Split/splitless capillary(default)

2. Split capillary

Packed Inlet

1. Single packed column inlet

2. Double packed column inlet

PC Software

1. Non counter-control FL9500

2. Counter-control FL9790(for 1&2 detector)

3. Counter-control FL9510(for 3 detectors)

Optional Sampling

Device

Changeover Valve

6-way valve or 10-way valve

Head Space Sampler

DK-3001A or HS-2 semi-automatic headspace sampler

Heat Analysis Sampler

RJX9700 with temp.-control or RJX9700 without temp.-control

Auto Sampler

RJX9700 with temp.-control or RJX9700 without temp.-control


3). ME-GC9790 Gas Chromatograph Equipment

Detector System :

Detector

Max. Operating

Temperature

Temp. Control

Accuracy

Sensitivity

FID

400℃

±0.1℃

≤1.0×10-11g/s[Hexadecane]

TCD

400℃

≥2500mV.ml/mg[Hexadecane]

ECD

350℃

≤1×10-14g/ml[γ-666]

FPD

400℃

P≤1.4×10-12g/s[Parathion-methyl]

S≤5.0×10-11g/s[Parathion-methyl]

NPD

400℃

N≤1×10-12g/s[Azobenzene];

P≤5×10-13g/s[Malathion]]


Column Oven Temperature Control :

Temp. control range: RT+8℃~399℃(0.1℃ increment)

Programming temp.-ramp speed: 0-40℃/min

Programming temp.-ramp:  6 steps

Fast cool down: 350~50℃≤3.5minutes


Accessories :

Standard Setup

Capillary Inlet

Split capillary

Packed Inlet

1. Single packed column inlet

2. Double packed column inlet

PC Software

1. Non counter-control FL9500

Optional Sampling

Device

Changeover Valve

6-way valve or 10-way valve

Headspace Sampler

DK-3001A or HS-2 semi-automatic headspace sampler

Heat analysis Sampler

RJX9700 with temp.-control or RJX9700 without temp.-control


3. Product Details of the Gas Chromatography Equipment


图片61(001).jpg

图片62(001).jpg

图片63(001).jpg


4. Application of the Double Beam Spectrometer

The type of GC Machine is widely Used in Fire investigation, petroleum, chemical industry, biochemistry, medicine and health, food industry, environmental protection and so on.


5. Laboratory GC Machine

Original: Guangzhou, China

Price: Negotiable

Voltage: 220v, 50Hz / 110V, 60Hz. The voltage can be as local demand.

Payment term: TT /Credit Card / Paypal / Western Union / LC, etc.

Delivery date: About 20 ~ 30 days after receive customer’s payment.

Delivery Method: By air / By express / By sea

Packing: Export Standard

Market: Oversea Market

Warranty: 12 months

MOQ: 1 Unit


6. Shipping

图片7.jpg

7. Our Advantages

We are the professional export manufacturer of the Optical equipment and instruments, with full experience for Precision GC systems products design, produce, sale, delivery, and after-sale service, etc., and we are being gold member on Alibaba for many years, so we are worthy of your trust !


8. Service of the High Quality Gas Chromatograph  